EYFR03 User Manual 86 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
Batch
USINT
Number of results required for a batch in the parameter.
Torque Unit
ENGUNIT
Unit used for torque fields
Torque
REAL
Torque of the tightening just performed.
Angle
UDINT
Angle of the tightening just performed.
VIN
SHORT_STRING
Max length 100
Reserved
USINT
Padding byte for devices requiring even connection point sizes and max
VIN length.
Total size: 31-132 bytes
112
Name
Data Type
Description
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Multi Sequence
Number
UINT
Sequence number of the running multi-parameter operation.
Multi Number
UINT
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Multi Type
USINT
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Parameter
UINT
Number of the parameter that produced the tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Count
USINT
Number of results performed in the current batch for the parameter.
Batch
USINT
Number of results required for a batch in the parameter.
Total size: 20 bytes
113
Name
Data Type
Description
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Reserved
USINT
Padding byte for devices requiring even connection point sizes.
Total size: 11-12 bytes
Input Connection Points for Current Qualifier Status
The connection points in this group provide a view of the current qualifier status and do not
provide any information about tightenings.
120
Name
Data Type
Description
Parameters
ARRAY of
STRUCT
of:
Status of up to 16 parameters currently running.
UINT
Parameter number (0 means parameter not running.)
USINT
Number of results performed in the current batch for the parameter.
USINT
Number of results required for a batch in the parameter.
Multi Number
UINT
Number of multi-parameter operation (job or group) currently running.
Ignored if 0.
Multi Type
USINT
Type of multi-parameter operation currently running:
1 – Group

Table of Contents