EYFR03 User Manual 85 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
• 13x: Last tightening data with fixed length string fields
Input Connection Points for Last Tightening Data
The connection points in this group will contain data about the last tightening. As such, they are
not updated after a parameter, group, or job selection until a tightening occurs.
110
Name
Data Type
Description
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Multi Sequence
Number
UINT
Sequence number of the running multi-parameter operation.
Multi Number
UINT
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Multi Type
USINT
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Parameter
UINT
Instance number of the parameter that produced the tightening
Parameter Name
SHORT_STRING
Name of the parameter. Max length 25
Parameter
Timestamp
DT
Timestamp of the last change to the parameter
Tool Serial
Number
SHORT_STRING
Serial number of the tool that produced the tightening. Max length 14
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Count
USINT
Number of results performed in the current batch for the parameter.
Batch
USINT
Number of results required for a batch in the parameter.
Torque Unit
ENGUNIT
Unit used for torque fields
Torque
REAL
Torque of the tightening just performed.
Min Torque
REAL
Minimum torque required for a tightening in the parameter.
Max Torque
REAL
Maximum torque required for a tightening in the parameter.
Angle
UDINT
Angle of the tightening just performed.
Min Angle
UDINT
Minimum angle required for a tightening in the parameter.
Max Angle
UDINT
Maximum angle required for a tightening in the parameter.
VIN
SHORT_STRING
Max length 100
Total size: 55-194 bytes
111
Name
Data Type
Description
Tightening ID
UDINT
ID number of the last tightening
Time
DT
Timestamp of the last tightening
Multi Sequence
Number
UINT
Sequence number of the running multi-parameter operation.
Multi Number
UINT
Instance number of multi-parameter operation (job or group) currently
running. Ignored if 0.
Multi Type
USINT
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Parameter
UINT
Number of the parameter that produced the tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Count
USINT
Number of results performed in the current batch for the parameter.