EYFR03 User Manual 84 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
172
Name
Data Type
Description
Item Number
UINT
Instance number of items to run. Deactivate any running parameter,
job, or group if 0.
Item Type
USINT
Type of item to run:
0 - Parameter
1 – Group
2 – Job
Ignored if Item Number is 0.
Batch Reset
USINT
When this value changes, the batch counts of the currently running
parameter or group is reset.
Suspend
BOOL
When set, suspends the unit without stopping a running parameter,
group, or job.
Batch
USINT
Sets the batch size for the selected parameter. If Item Type is not 0
(Parameter), this value is ignored. If this value is 0, the parameter size
stored in the EYFR03 will be used.
VIN
USINT[100]
Total size: 106 bytes
181
Name
Data Type
Description
Item Number
UINT
Instance number of items to run. Deactivate any running parameter,
job, or group if 0.
Item Type
USINT
Type of item to run:
0 - Parameter
1 – Group
2 – Job
Ignored if Item Number is 0.
Batch Sizes
USINT[16]
A temporary batch size to use for each tool or 0 to make no
modification.
Batch Reset
WORD
16-bit word with each bit used to reset the batch of a tool when set (bit
0 resets tool 1, bit 1 resets tool 2, etc.)
Tool Suspend
WORD
16-bit word with each bit used to suspend a tool (bit 0 set suspends tool
1, bit 1 set suspends tool 2, etc.)
Qualifier Suspend
BOOL
When set, suspends the unit without stopping a running parameter,
group, or job.
Total size: 24 bytes
Note that the values in this point refer to tools, but the EYFR03 runs parameters. This means
that you must select a parameter, group, or job using the tools you want to control with this
connection point. If a tool is not active in the selected parameter, group, or job, attempts to
control them will be ignored.
Input (T->O) Connection Points
This section defines the connection points are used by EYFR03 to send output data to the
network. The connection points are in the range 100-129 and are grouped by their content.
• 10x: Connection points provided for backwards compatibility with the EYFR01. (Detailed in
the Input Connection Points for Backwards Compatibility section later in this chapter)
• 11x: Last tightening data
• 12x: Current qualifier status

Table of Contents