EasyManua.ls Logo

Panasonic EYFR03 - Page 91

Panasonic EYFR03
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EYFR03 User Manual 91 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
EE Time
CHAR[6]
ASCII digits of time of last EEPROM write in HHMMSS format.
EE Date
CHAR[6]
ASCII digits of date of last EEPROM write in MMDDYY format.
Torque
CHAR[6]
ASCII digits and decimal point (‘.’) representing the value. Not used by
the EYFR03.
Min Torque
CHAR[6]
ASCII digits and decimal point (‘.’) representing the value. Not used by
the EYFR03.
Max Torque
CHAR[6]
ASCII digits and decimal point (‘.’) representing the value. Not used by
the EYFR03.
Units
USINT
Character representing the units of the torque. Not used by the EYFR03.
Angle
CHAR[5]
ASCII digits representing the value. Not used by the EYFR03.
Min Angle
CHAR[5]
ASCII digits representing the value. Not used by the EYFR03.
Max Angle
CHAR[5]
ASCII digits representing the value. Not used by the EYFR03.
Tool Type 1
CHAR[3]
Type of tool in parameter 1. See Tool Type for values.
Tool Type 2
CHAR[3]
Type of tool in parameter 2. See Tool Type for values.
Tool Type 3
CHAR[3]
Type of tool in parameter 3. See Tool Type for values.
Tool Type 4
CHAR[3]
Type of tool in parameter 4. See Tool Type for values.
Tool Type 5
CHAR[3]
Type of tool in parameter 5. See Tool Type for values.
Tool Type 6
CHAR[3]
Type of tool in parameter 6. See Tool Type for values.
Tool Type 7
CHAR[3]
Type of tool in parameter 7. See Tool Type for values.
Tool Type 8
CHAR[3]
Type of tool in parameter 8. See Tool Type for values.
Total size: 102 bytes
101
This connection point corresponds to the mask 1 of the EIP network card for the EYFR01.
Name
Data Type
Description
Parameter
CHAR
‘A’-‘H’
Tightening Status
CHAR
Status of the last tightening. One of:
‘O’ – Good tightening
‘N’ – Bad tightening or no tightening performed since the last parameter
change.
Tightening Type
CHAR
Type of the last tightening. One of:
‘B’ – Good tightening that finished a batch
‘C’ – Good tightening that did not finish a batch
‘R’ – Bad tightening
‘N’ – No tightening performed since the last parameter change
Count
USINT
The count of the last tightening.
Batch
USINT
The batch size of the last tightening
Rolling Count
UINT
Number of tightenings that have occurred.
Total
UINT
Number of batches completed in the parameter.
Reserved
USINT
Total size: 10 bytes
102
This connection point corresponds to the mask 2 of the EIP network card for the EYFR01.
Name
Data Type
Description
Tightening status
CHAR
Status of the last tightening. One of:
‘O’ – Good tightening
‘N’ – Bad tightening or no tightening performed since the last parameter
change.
Rolling Count
UINT
Number of tightenings that have occurred.
Reserved
USINT

Table of Contents