What to Check If a Problem Occurs FP2 Multi-wire Link Unit
A-4
A.2 Confirming the Mode Being Used
A.2 Confirming the Mode Being Used
Procedure 1
To see if the mode being used is appropriate for the objective, check the mode selector
switches (2) on the rear panel.
Mode What to check Mode selector switches(2)
MEWNET-W
mode
Check to see if all of the units in the link are in the
MEWNET-W mode.
If the problem is not corrected, regardless of whether
or not the units are in the MEWNET-W mode, see
chapter 5 of the FP3/FP5 W type (wire) link system
manual.
MEWNET-W2
mode
Check to see if all of the units in the link are in the
MEWNET-W2 mode.
If the problem is not corrected, regardless of whether
or not the units are in the MEWNET-W2 mode, refer to
MEWNET-W2 Wire Link Specification Explanations.
MEWNET-F
mode
Check to see if all of the units in the link are in the
MEWNET-F mode.
If the problem is not corrected, regardless of whether
or not the units are in the MEWNET-F mode, see
chapter 8 of the FP3/FP5 Remote I/O system manual.
.
Note
The setting of the mode selector switches (2) should be changed
with the power off.