6. Install the new double feed prevention roller.
Align the shaft that is shaped as indicated by A with the notch in the roller mount (B), and then insert
the shaft in the notch. Push the shaft on the opposite side (C) until it clicks into place.
1
1
3
2
2
Notice
After you install the double feed prevention roller, make sure that the shaft is inserted into the tab,
and that the shaft will not rotate or move. If the roller is not installed correctly, it may cause double
feeding or a paper jam.