EasyManua.ls Logo

Panasonic KX-TDA200 - Page 163

Panasonic KX-TDA200
824 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Value Range
Automatic, 6 dB, 12 dB, 18 dB, 24 dB
Maintenance Console Location
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
First Dial Timer (CO)
Specifies
the minimum time that the PBX waits after seizing a CO line, before sending the dialed digits to the
telephone company. This allows the telephone company to have enough time to accept the dialed digits
correctly.
Default
1.0 s
Value Range
0.5 ´ n (n=1–16) s
Maintenance Console Location
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
First Dial Timer (DID/TIE)
Specifies
the minimum time that the PBX waits after seizing a DID or TIE line, before sending the dialed digits
to the telephone company or to another PBX. This allows the telephone company or the other PBX to have
enough time to accept the dialed digits correctly.
Default
64 ms
Value Range
32 ´ n (n=1–255) ms
Document Version 2008-11 PC Programming Manual 163
3.16 [1-1] Slot—Card Property - T1 type (KX-TDA100/KX-TDA200/KX-TDA600 only)

Table of Contents

Other manuals for Panasonic KX-TDA200

Related product manuals