Feature Manual References
9.1.3 ICD Group Features—Log-in/Log-out
Maximum No. of Busy Extension
Specifies
the number of extensions that can accept calls simultaneously in the incoming call distribution group.
Default
Max.
Value Range
Max.: Call arrives at an idle extension.
1–32 : Call will not arrive at an idle extension when the number of busy extensions exceeds the assigned
number.
Maintenance Console Location
5.12 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
9.1.2 ICD Group Features—Group Call Distribution
Last Extension Log-out
Specifies whether the last extension logged-in to the incoming call distribution group is allowed to log out.
Default
Enable
Value Range
Disable, Enable
Maintenance Console Location
5.12 [3-5-1] Incoming Call Distribution Group
—Group Settings
Programming Manual References
None
Feature Manual References
9.1.3 ICD Group Features—Log-in/Log-out
418 PC Programming Manual Document Version 2008-11
5.12 [3-5-1] Incoming Call Distribution Group—Group Settings