No.SX-DSV01676 - 29 -
R2 Motor Company, Matsushita Electric Industrial Co., Ltd.
<Wiring method to terminal block>
Make the wiring to power connector, X1 and X2 in the following procedures.
Wiring method
1. Peel off the insulation cover of the cable.
2. Insert the cable to the connector. There are 2 inserting methods as below.
(a) Use the attached handle lever
(b) Use the standard screw drive(blade width: 3.0 to 3.5mm).
(a) Using a handle lever
1)
Press the lever on the handle
slot to push down the spring.
2)
Insert the cable until it hit the
insertion slot (round hole)
while pressing down the lever.
3)
Release the lever.
(b) Using a standard screw drive
1)
Press the screw drive to the
handle slot to push down the
spring.
2)
Insert the peeled off cable until
it hits the insertion slot (round
hole).
3)
Release the screw drive.
* You can pull out the cable by pushing down the spring.
Cautions
・Peel off the cable by specified 8 to 9mm.
・Remove the connector from the drive while making a wiring.
・ Insert one cable into one insertion slot.