6.OPERATION
<Trigger condition tab>
Set the trigger condition.
Set the trigger of actual speed: It is valid with check.
Single trigger: It is measured only once with check.
Without check it continues to be measured until
you click Stop.
Trigger level: Set the actual speed to trigger. You can
set plus or minus with .
Slope: Set the slope to trigger. Select Start or Finish.
Trigger position: Select where to start trigger for the measuring
period.
<Vertical axis/Horizontal axis tab>
Set the display condition of waveform graphic.
Y axis: Set the magnification and position of Speed,
Torque, Position error and In-position.
Auto range: The magnification and position is automatically
set optimum.
Initialize vertical axis: Initialize the display position.
X axis: Set the Magnification and position of horizontal
axis (Time axis).