8) Press the <ENTER> button.
f The projector will go into the adjustment mode (the time is blinking).
9) Press qw to select “hour” or “minute”, and press as or the number (<0> - <9>) buttons to set a
time.
f Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows
setting of only the minute in increments of one minute between 00 and 59.
f When the time is not specied, select [OFF] between 23 and 00 of the hour, or between 59 and 00 of the
minute.
10) Press the <ENTER> button.
f [CALIBRATION TIME] is set.
f Brightness and color are measured at the specied time. The dynamic contrast function does not operate
during measurement.
11) Press as to select [CALIBRATION MESSAGE].
12) Press qw to switch the item.
f The items will switch each time you press the button.
[ON] Displays the message while executing the calibration.
[OFF] Does not display the message while executing the calibration.
13) Press as to select [APPLY].
14) Press the <ENTER> button.
f When [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP] is set to anything other than [OFF], the
brightness and white balance of light source at the time when the <ENTER> button is pressed is recorded
as the standard brightness and white balance.
f The group name is displayed in the screen of the projectors set as the same group when the <ENTER>
button is pressed while [LINK] is set to an item from [GROUP A] to [GROUP D].
LINK GROUP A
15) When the confirmation screen is displayed, press qw to select [APPLY], and press the <ENTER>
button.
Note
f When [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP] is set to [AUTO] or [PC], keep the shutter function disabled (shutter:
open) for at least two minutes, since the brightness sensor calibration is performed after the [BRIGHTNESS CONTROL SETUP] setting has
been completed.
f If the shutter function is enabled (shutter: closed) within approximately 10 minutes after the light source has turned on while [CONSTANT
MODE] in [BRIGHTNESS CONTROL SETUP] is set to [AUTO] or [PC], brightness and color cannot be measured. Therefore, brightness
may be corrected approximately two minutes after the shutter function is disabled (shutter: open).
f Since the brightness and the color of the light source do not stabilize for approximately eight minutes after turning on the light source when
the projector operates with [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], the brightness and the color
of the light source will be automatically measured approximately eight minutes after the light source is turned on. A correction is made based
on this measurement result so that the brightness and the color will be the same as the standard brightness and color when adjusted with
the brightness control.
f When the projector operates with [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], the items of
[OPERATING MODE] and [LIGHT OUTPUT] cannot be changed.
f When the projector operates with [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO], and [LINK] set to [OFF], the
brightness will be corrected until it reaches the value set in [MAX LIGHT OUTPUT LEVEL].
f The variation in brightness may increase due to dust accumulating on the lens, screen, or inside the projector, depending on the installation
environment of the projector.
f When the variation in brightness has increased due to aging of the light source, or when you replaced the light source, readjust the
brightness control.
f When the projector is used continuously for more than 24 hours, set the [CALIBRATION TIME] in [BRIGHTNESS CONTROL SETUP]. If it is
not set, correction will not be performed automatically.
f The brightness control function and the dynamic contrast function will operate simultaneously, but the dynamic contrast function will not
operate while measuring the brightness and the color.
f The [CALIBRATION TIME] setting will be reected when you enter the time.