r Cautions when setting the projectors
f If you want to use the projector other than the way of setting on the desk/oor with the adjustable feet or mounting on the
ceiling, use the three screw holes for ceiling mounting (as shown below) to x the projector.
(Screw: M4; Depth of the screw hole: 8 mm (5/16″); Torque: M4 1.25 ± 0.2 N·m)
In addition, always keep a gap of more than 20 mm (25/32″) between the bottom of the projector and installation surface.
Make sure that there is no clearance of at least 20 mm (25/32″) between the screw holes for ceiling mounting and the
installation surface by inserting supports (metallic) between them.
The positions of adjustable feet and the
screw holes for ceiling mounting
Adjustable feet
Over 20 mm
(25/32″)
Installation surface
Screw holes for ceiling
mounting (M4)
f
Make sure the air ow into the air intake
port (bottom), failure to do so may cause the
projector cannot work.
f Do not stack the projectors.
f Do not use the projector supporting it by the top.
f Do not block the ventilation ports (intake and exhaust) of the projector.
f Avoid heating and cooling air from the air conditioning system directly blow to the ventilation ports (intake and exhaust) of
the projector.
f Do not install the projector in a conned space.
When placing the projector in a conned space, a ventilation and/or air conditioning system is required. Exhaust heat may
accumulate when the ventilation is not enough, triggering the protection circuit of the projector.
Security
Take safety measures against following incidents.
f Personal information being leaked via this product.
f Unauthorized operation of this product by a malicious third party.
f Interfering or stopping of this product by a malicious third party.
Security instruction (x pages 76, 93)
f Make your password as difcult to guess as possible.
f Change your password periodically.
f Panasonic or its afliate company never inquires a password directly to a customer. Do not tell your password in case you
receive such an inquiry.
f The connecting network must be secured by rewall or others.
f Set a password for web control and restrict the users who can log in.
500 mm (19-11/16")
or longer
1 000 mm (39-3/8")
or longer
7 mm (9/32")
or longer
500 mm (19-11/16")
or longer
200 mm (7-7/8")
or longer
Air intake port
(bottom)
ENGLISH - 15
Chapter 1 Preparation - Precautions for use