Example of E-mail sent for an error
Mail with the contents shown below is sent when an error has occurred.
=== Panasonic projector report(ERROR) ===
Projector Type : PT-VW355N
Serial No : 000000000
----- check system -----
FAN [ OK ]
INTAKE AIR TEMPERATURE
[ OK ]
EXHAUST AIR TEMPERATURE
[ OK ]
OPTICS MODULE TEMPERATURE
[ OK ]
LAMP REMAIN TIME
[ OK ]
LAMP STATUS [ OK ]
APERTURE (CONTRAST-SHUTTER)
[ OK ]
AIR FILTER
[ FAILED ]
(Error code 00 00 00 20 00 00 00 00)
Intake air temperature : 31 degC / 87 degF
Exhaust air temperature : 37 degC / 98 degF
Optics module temperature : 39 degC / 102 degF
PROJECTOR RUNTIME 800 H
LAMP NORMAL
500 H
LAMP ECO 700 H
LAMP REMAIN
4000 H
-------- Current status ---------
MAIN VERSION 1.00
NETWORK VERSION 1.00
SUB VERSION 1.00
LAMP STATUS LAMP=OFF
INPUT RGB
----- Wired Network conguration -----
DHCP Client OFF
IP a d d r e ss 192.168.10.100
M AC a d d ress 04:20:9A:00:00:00
----- Wireless Network conguration -----
DHCP Client OFF
IP a d d r e ss 192.168.0.100
M AC a d d ress 04:20:9A:00:00:00
----- Memo -----
[Port set up] page
Set the port number used for command control.
Click [Detailed set up] → [Port set up].
3
1
2
1 [COMMAND PORT]
Set the port number used for command control.
2 [Wake on LAN PORT]
When [STANDBY MODE] is set to [NETWORK], set the
port number used for the Wake on LAN function.
3 [Submit]
Update the settings.