Chapter 5: System Configuration
35
Receiver Events
The following receiver account events are pre-set in the system. The receiver events are sent to
the monitoring station’s automation software and to the serial output.
Memory card not present - sends a message to the monitoring station’s automation soft-
ware when the memory card could not be detected in the IPR512 Receiver.
Memory card error - sends a message to the monitoring station’s automation software
when the memory card could not be written to or cannot be initialized.
Memory card restore - sends a message to the monitoring station’s automation software
when “memory card not present” or “memory card error” has been resolved.
Backup restore from memory card - sends a message to the monitoring station’s automa-
tion software when a backup has been restored from the memory card.
IPR512 power up - sends a message to the monitoring station’s automation software when
the IPR512 Receiver has been powered up.
Automation software communication failure - sends a message to the monitoring sta-
tion’s automation software and to the serial output port when communication with the auto-
mation software could not be established.
Automation software communication restore - sends a message to the monitoring sta-
tion’s automation software and to the serial output port when communication with the auto-
mation software has been restored.
Account database reached 75% - sends a message to the monitoring station’s automation
software when the account database account capacity has reached 75%.
Account database reached 100% - sends a message to the monitoring station’s automa-
tion software when the account database account capacity has reached 100%.
Account cannot register, database is full - sends a message to the monitoring station’s
automation software when an attempt to register has been done on a full database.
Web login - sends a message to the monitoring station’s automation software when a suc-
cessful login attempt has been made via the IPR512 Account Management System.
NTP server failure - sends a message to the monitoring station’s automation software when
communication to the NTP server cannot be established.
NTP server restore - sends a message to the monitoring station’s automation software
when communication to the NTP server is restored.
LAN network connection failure -sends a message to the monitoring station’s automation
software when communication failure has occurred on the LAN.
LAN network connection restore -sends a message to the monitoring station’s automation
software when communication on the LAN has been restored.
WAN1 network connection failure - sends a message to the monitoring station’s automa-
tion software when a network failure has occurred.
WAN1 network connection restore - sends a message to the monitoring station’s automa-
tion software when the network connection has been restored.
WAN1 internet connection failure - sends a message to the monitoring station’s automa-
tion software when communication to the internet (to the polling website defined in the
Receiver Configuration menu) via WAN1 cannot be established.
WAN1 internet connection restore - sends a message to the monitoring station’s automa-
tion software when communication to the internet (to the polling website defined in the
Receiver Configuration menu) via WAN1 has been restored.
WAN2 network connection failure - sends a message to the monitoring station’s automa-
tion software when a network failure has occurred.