MG5000+ / MG5050+ Installation Guide
29
Keyswitch Programming
Keyswitch Numbering
On-board hardwire control panel zones only.
Keyswitch Numbering allows you to assign any hardwired input in the system to any of the 32 keyswitch zones in the control panel.
Keyswitch Definitions
Keyswitch Definitions determine how a keyswitch is used.
Maintained Keyswitch
On-board hardwire control panel zones only.
To arm a partition using the Maintained Keyswitch, turn the switch from the
ON to the OFF position. Disarm it by setting the key on the ON position.
Momentary Keyswitch
On-board hardwire control panel zones only.
To arm or disarm a partition using the Momentary Keyswitch, turn the keyswitch to the
ON position for three seconds, then turn it to the OFF position.
Keyswitch Options
Each keyswitch zone can be programmed with one or more options.
Stay/Sleep Disarm Option (Keyswitch)
On-board hardwire control panel zones only: Option 4
When enabled, the keyswitch can only disarm assigned Stay or Sleep armed partitions. When option [4] is disabled, the keyswitch can disarm partitions armed using
any arming method.
Arm Only (Keyswitch)
On-board hardwire control panel zones only: Option 5
When enabled, the keyswitch can only arm assigned partitions. The type of arming is determined by the other Keyswitch Options selected.
Stay Arming (Keyswitch)
On-board hardwire control panel zones only: Option 6
Activating the keyswitch will Stay Arm the partition.
Sleep Arming (Keyswitch)
On-board hardwire control panel zones only: Option 7
Activating the keyswitch will Sleep Arm the partition.
Only one of the arming options (Stay, Force, Instant and Regular) can be selected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox MG5000+ and is the answer not in the manual?

Paradox MG5000+ Specifications

General IconGeneral
StayD ModeYes
Zones32
Wireless ExpansionYes
Remote ControlYes
PGMs2
Remote ControlsCompatible with MG/SP remote controls
Battery Backup12V 7Ah battery (not included)
Outputs2 programmable outputs