MG5000+ / MG5050+ Installation Guide
43
Zone Restore Report Options
Section [801]: Zone Options
Option [2] OFF= Report On Bell Cut-Off (default)
Option [2] ON= Report On Zone Closure
With option [2] OFF, the panel will send the Zone Alarm Restore report codes to the monitoring station when the zone has returned to normal and the Bell Cut-Off
Timer has elapsed. With option [2] ON, the panel will send the Zone Alarm Restore report codes to the monitoring station as soon as the zone returns to normal or
when the system is disarmed.
Telephone Line Monitoring (TLM)
When enabled, the system verifies the existence of a telephone line once every second. A line test failure occurs when the TLM detects less than 3 volts for the
period defined by the TLM Fail Timer. If the line test fails, the control panel’s
STATUS LED flashes and generates one or more conditions as defined by the TLM
settings below. These will be restored when the control panel detects the telephone line again. Please note that when the dialer detects an incoming call, the TLM
test will stop for 1 minute.
Section [800]: Dialer Options
[1] OFF / [2] OFF: TLM Disabled
[1] OFF / [2] ON: Trouble Only
Upon line test failure, a TLM Trouble will appear in the keypad’s trouble display (see “Trouble Display” on page 51).
[1] ON / [2] OFF: Audible Alarm If System Armed
Upon line test failure, a TLM Trouble will appear in the keypads trouble display (see “Trouble Display” on page 51) and if the system is armed, the control panel will
generate an audible alarm.
[1] ON / [2] ON: Silent Alarm Becomes Audible
Upon line test failure, a TLM Trouble will appear in the keypads trouble display (see “Trouble Display” on page 51) and causes a silent zone or silent panic alarm to
switch to audible.
TLM Fail Timer
Section [830]
016 to 255 x 2 seconds, Default = 32 seconds
If TLM does not detect the existence of a telephone line for the duration of this period, the control panel will generate the condition(s) defined by the TLM options.
Pager Reporting Delay
Section [834]: Communication Timers
000 to 255 seconds, Default = 20 seconds
When using the Pager Reporting Format, the control panel will wait for the Pager Delay period before transmitting the report codes. This is to allow time for the
pager system to provide a dial tone or to bypass the “welcome” message before sending data.
Pager Reporting Message Repetition
Section [835]: Communication Timers
000 to 255 times, Max. 10, Default = 3
When using the Pager Reporting Format, the control panel will repeatedly send the report codes to the pager until the transmission has been acknowledged.
Personal Reporting Delay
Section [836]: Communication Timers
000 to 255 times, Max. 127, Default = 5
When using the Personal Reporting Format, the control panel will wait for the Personal Delay period before transmitting the report codes. This is to allow time for
the system to provide a dial tone or to bypass the “welcome” message before sending data. This section applies to the Plug-in Voice Dialer when using a
VDMP3.
Personal Reporting Message Repetition
Section [837]: Communication Timers
000 to 255 times, Max. 10, Default = 3
When using the Personal Reporting Format, the control panel will repeatedly send the report codes to the pager until the transmission has been acknowledged.
This section applies to the Plug-in Voice Dialer when using a VDMP3.
Disable Reporting
Sections [800]
Option [1] OFF= Dialer Activated (default)
Option [1] ON= No Dialer
With this option disabled (default), the control panel will continue to report events. With the option enabled, reporting is disabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox MG5000+ and is the answer not in the manual?

Paradox MG5000+ Specifications

General IconGeneral
StayD ModeYes
Zones32
Wireless ExpansionYes
Remote ControlYes
PGMs2
Remote ControlsCompatible with MG/SP remote controls
Battery Backup12V 7Ah battery (not included)
Outputs2 programmable outputs

Related product manuals