MG5000+ / MG5050+ Installation Guide
39
Clear Reporting Codes
Section [966]: Clear Reporting Codes
Option [1] OFF= Clear zone reporting codes
Option [1] ON= Clear zone reporting codes (default)
Option [2] OFF= Clear user reporting codes
Option [2] ON= Clear user reporting codes (default)
Option [3] OFF= Clear arm/disarm/alarm reporting codes
Option [3] ON= Clear arm/disarm/alarm reporting codes (default)
Option [4] OFF= Clear trouble reporting codes
Option [4] ON= Clear trouble reporting codes (default)
Enable all options you want to clear. The respective sets of reporting codes will be cleared after exiting the section.
Reset Reporting Codes
Section [967]: Reset Reporting Codes
Option [1] OFF= Reset zone reporting codes
Option [1] ON= Reset zone reporting codes (default)
Option [2] OFF= Reset user reporting codes
Option [2] ON= Reset user reporting codes (default)
Option [3] OFF= Reset arm/disarm/alarm reporting codes
Option [3] ON= Reset arm/disarm/alarm reporting codes (default)
Option [4] OFF= Reset trouble reporting codes
Option [4] ON= Reset trouble reporting codes (default)
Enable all options you want to reset to default. The respective sets of reporting codes will be reset after exiting the section.
Monitoring Station Telephone Numbers
Section [815] = Phone#1, [816] = Phone#2, [817] = Backup Phone#, [818] = Pager #, [819] = Numeric Message Sent with Pager Reporting: Up to 32 digits
The control panel can dial up to 2 different monitoring station telephone numbers. You can enter any digit from 0 to 9 and any special keys or functions up to a
maximum of 32 digits. After the maximum dialing attempts (see “Maximum Dialing Attempts” on page 41) to one monitoring station telephone number have failed,
the control panel will then dial the backup telephone number. If the Alternate Dial Option (see “Alternate Dial Option” on page 41) is enabled, the control panel will
dial the programmed backup telephone number after every failed attempt. If no backup telephone number is programmed, the control panel will never report to
the backup telephone number. Also see “Delay Between Dialing Attempts” on page 41.
Personal Dialing Numbers
Personal Dialing numbers are personal numbers (e.g. cellular, office) that the panel can call in case of an alarm or panic. To program these five numbers see the
Communicator Menu in either the Master or User Quick Menu. To set the call parameters, see options [5], [6], and [7] of section [804].
The panel will call these personal numbers if programmed in the event of any panic or alarm (default) and sound a bell tone. To program the delay between the call
attempts, see section [832]. The panel can also be programmed to delay before sounding the bell tone, which can be programmed in section [836].
The default delay is 20 seconds. To determine the length of time the bell tone sounds on the phone line, see section [837]. The default value is 003, meaning the 10
second bell tone will repeat itself 3 times after the initial sequence (total= 40 seconds).
Press Action or Value
[OFF]
*
[BYP]
#
[MEM]
switch from pulse to tone dialing or vice versa
[TBL]
4-second pause
[SLEEP]
deletes current digit
[]
inserts blank space

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox MG5000+ and is the answer not in the manual?

Paradox MG5000+ Specifications

General IconGeneral
StayD ModeYes
Zones32
Wireless ExpansionYes
Remote ControlYes
PGMs2
Remote ControlsCompatible with MG/SP remote controls
Battery Backup12V 7Ah battery (not included)
Outputs2 programmable outputs

Related product manuals