Page #37 background image
Magellan / Spectra SP 37
Reset System Report Codes
Special Arming Report Codes (Default = FF)
Special Disarming Report Codes (Default = FF)
Special Alarm Report Codes (Default = FF)
System Trouble Report Codes (Default FF)
System Trouble Restore Codes (Default FF)
[967] Reset Report Codes
Option OFF ON
[3] Reset arm/disarm/alarm report codes to default*
Disabled
Enabled
[4] Reset trouble report codes to default*
Disabled
Enabled
[5] Reset system special report codes to default*
Disabled
Enabled
* Ensure all other options are deselected. Press [
ENTER] to reset the respective set of report codes before exiting the section.
Section Data Description Section Data Description
[860] ___/___ Auto-arming [861] ___/___ Quick arming
___/___ Late to close ___/___ Arming via PC
___/___ No movement ___/___ Arming with Keyswitch
___/___ Partial arming ___/___ N/A
Section Data Description
[862] ___/___ Cancel auto-arm
___/___ Disarming via PC
___/___ Cancel alarm with user or WinLoad / BabyWare
___/___ Cancel paramedic
Section Data Description Section Data Description
[863] ___/___ Emergency panic [864] ___/___ Zone shutdown
___/___ Auxiliary panic ___/___ Duress
___/___ Fire panic ___/___ Keypad lockout
___/___ Recent closing ___/___ Paramedic alarm
Section Data Description Section Data Description
[865] ___/___ N/A [868] ___/___ Module power fail
___/___ AC failure ___/___ Module low/no battery*
___/___ Battery failure ___/___ Wireless zone low battery*
___/___ Auxiliary supply ___/___ Wireless zone supervision lost*
[866] ___/___ Bell output overload [869] ___/___ Wireless module supervision lost*
___/___ Bell output disconnect ___/___ Wireless module tamper*
___/___ Timer loss ___/___ N/A
___/___ Fire loop trouble ___/___ N/A
[867] ___/___ Fail to communicate
___/___ RF jamming *Does not apply to SP4000 systems
___/___ Module lost
___/___ Module tamper
Section Data Description Section Data Description
[870] ___/___ TLM [873] ___/___ Module power fail
___/___ AC failure ___/___ Module low/no battery*
___/___ Battery failure ___/___ Wireless zone low battery*
___/___ Auxiliary supply ___/___ Wireless zone supervision lost*
[871] ___/___ Bell output overload [874] ___/___ Wireless module supervision lost*
___/___ Bell output disconnect ___/___ Wireless module tamper*
___/___ Timer loss ___/___ N/A
___/___ Fire loop trouble ___/___ N/A
[872] ___/___ Fail to communicate
___/___ RF jamming *Does not apply to SP4000 systems
___/___ Module lost
___/___ Module tamper

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah
PGM Outputs2