COMSPHERE 3600 Series Data Service Units
E-8 December 1996 3610-A2-GB46-60
Table E-5
(4 of 4)
Device Health and Status Messages
Message ActionCondition
Prt
nnn
Disable Transmitter at port
nnn
(01—06, All) is
disabled.
Use the Control branch’s control option TxCtl to
enable the port.
Prt
nnn
Stream Term Streaming terminal. DTE at port
nnn
(01—06,
All) has its RTS lead turned ON longer than the
predefined time.
Refer to configuration option AntiStream. Verify
DTE operation.
Redun Fan Alarm Indicates a problem with the fan on the –48 Vdc
Central Office Power Unit.
Check NMS adapter cable connection to
48 Vdc power supply cable connections. If
okay, call your sales or service representative.
Redun Pwr Alarm Indicates a problem with the power on the
48 Vdc Central Office Power Unit.
Check NMS adapter cable connection to
48 Vdc power supply cable connections. If
okay, call your sales or service representative.
Subnetwrk Alarm A major alarm was set Off by one of the devices
in your subnetwork.
Check the Subnetwork Health and Status report
and Table E-6.
Sub-normal Speed The DBM is operating at a dial backup speed
less than the DSU and the DDS network speed.
Set the configuration option DBM Rate(Kbps) to
the DDS network data rate.
Subtree Truncat Downstream health and status information has
been truncated because of an overflow of the
system limits.
Clear any alarms to decrease the amount of
information reported.