D-140 Programming
DC590+ DRV Series DC Digital Drive
Operation Description
PULSE TRAIN
Creates a pulsed FALSE / TRUE output of programmable frequency.
INPUT A enables the pulse train when TRUE, disables when FALSE. INPUT B sets the length of the on part of the pulse in
seconds (1 = 1 second). INPUT C sets the length of the off part of the pulse in seconds (1 = 1 second).
input_a
output
ON time (input_b)
OFF time (input_c)