D-142 Programming
DC590+ DRV Series DC Digital Drive
Operation Description
UP/DOWN COUNTER
input A
input B
output
0
INPUT A provides a rising edge trigger to increment the output count by one.
INPUT B provides a rising edge trigger to decrement the output count by one.
INPUT C holds the output at zero.
The output starts at zero. The output is limited at ±300.00.
(A*B)/C ROUND
The OUTPUT is set to (INPUT A * INPUT B) / (INPUT C). This is the same as (A*B)/C (enumerated value 3) except that the
result is rounded.
WINDOW
NO HYST
This is the same as WINDOW (enumerated value 19) except that there is no hysteresis when inside the `window’. Thus, from
the diagram given in WINDOW, if INPUT B = 5 and INPUT C = 4 then the range is 3 to 7.