4. System sizing
4.1. Recommendations
4.1.1. Injector/DLFC/Refill flow controller - Valve configuration
4.2. Cycle time calculation
The 600 series controller will automatically set the cycle time based on the program or so called unit
number selected when programming the system (see 6.6. System selection, page 30). Make sure the
programmed unit# is corresponding to your actual system and valve configuration.
Vessel
diameter [In]
Injector Flow
control
Refill flow
control
[gpm]
Backwash flow
control
[gpm]
Controller
Time Clock 604 Volumetric 606
6 E [yellow] 0.14 0.9 4001737 4001738
7 F [peach] 0.14 1.2 4001737 4001738
8 G [tan] 0.14 1.6 4001737 4001738
9 H [lt purple] 0.14 2.0 4001737 4001738
10 J [lt blue] 0.33 2.5 4001741 4001742