Installer Manual Autotrol 368 / 604-606 - Maintenance
40 / 54 Ref. MKT-IM-007 / A - 16.12.2016
9.2.4. Cleaning the backwash flow controller
No. Operation
A Remove the clip (1).
B Unscrew the backwash controller (4) by hand.
Caution
Pay attention to not lose the backwash controller ball (3) that is inside.
C Clean the backwash controller (4) using a soft brush or compressed air.
D Clean the backwash controller grooves and backwash controller chamber (2).
E Reverse above procedure steps to rebuild.
Note
Remember to put the backwash controller ball (3) inside the plug when reassembling.
Caution
When reassembling the backwash controller (4), slowly screw by hand or by mean of a Torx
key.