Pentair AUTOTROL 604 - Injection Flow Rates; Salt Amount Definition

Pentair AUTOTROL 604
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Autotrol 368 / 604-606 - System sizing
Ref. MKT-IM-007 / A - 16.12.2016 17 / 54
4.3. Injection flow rates
The following graphs represent the injectors flow rate as a function of the inlet pressure for the
different injector sizes.
4.4. Salt amount definition
The salt amount is set in kilograms of salt use for each regeneration. This setting will greatly
influence the system. Make sure this setting is aligned with your actual system size and unit#
programmed.
TOTAL
BRINE DRAW
psi
Injector "F" (Peach)
For 7" Tanks
Injector "G" (Tan)
For 8" Tanks
Injector "H" (Light Purple)
For 9" Tanks
Injector "J" (Light Blue)
For 10" Tanks
gpm
psi
psi
psi
bar bar
bar
bar
gpm
gpm
gpm
m
3
/h
m
3
/h
m
3
/h
m
3
/h
RINSE