9.2.2. Cleaning the refill flow controller
9.2.3. Cleaning the injector valve and the injector screen
No. Operation
A Using a Torx key, unscrew and extract the refill flow controller (4).
B
Clean the refill flow controller (4) using compressed air or with a soft brush.
Make sure the refill controller groove is perfectly clean.
C Check for O-rings integrity.
D Check for ball (5) integrity (if present).
E Clean the refill flow controller chamber (6) before reinserting the refill flow controller (4).
F Reverse above procedure steps to rebuild.
No. Operation
A Using a Torx key, unscrew and remove the injector cap (3).
Caution
Take care not to damage the injector (2).
B Using pliers, gently extract the injector (2) from valve body.
C Clean the injector (2) using compressed air, a soft brush or possibly a pin.
D Unclip the injector screen (1) and clean it with a soft brush.
Note
Use of descaling agent such as white vinegar might be required in case of impurities on the
injector screen (1) and on the injector (2).
E Check for O-rings integrity.
F Reverse above procedure steps to rebuild.
Note
The injector screen is assembled on the injector.
Note
Use your finger to press on the injector to position it correctly when putting it back into the
valve.