Installer Manual Autotrol 368 / 604-606 - Installation
Ref. MKT-IM-007 / A - 16.12.2016 25 / 54
To remove a clip:
A Turn off water and release water pressure at the valve.
B Push the water line connectors (3) into the bypass and valve. This will help release O-rings that
may have seated in place.
C Remove the clips (1) by inserting a flat screwdriver (2) under the top centre of the clip and lifting
(prying up).
Caution
Do not use pliers to remove a clip. It is likely the clip will break.