Installer Manual Autotrol 368 / 604-606 - Troubleshooting
48 / 54 Ref. MKT-IM-007 / A - 16.12.2016
* 368 valve with 606 controller only.
Issue Cause Solution
No conditioned
water after
regeneration.
No brine in brine tank. Add brine to brine tank.
Injector plugged.
Clean the injector and screen. See
9.2.4. Cleaning the backwash flow
controller, page 40.
Backwashes or
purges at
excessively low or
high rate.
Incorrect drain controller used. Replace with correct size controller.
No drain line flow controller.
Install drain line flow controller. See
5.7. Drain line flow controller, page 23.
Restricted drain line. Remove restriction.
Run out of
conditioned water
between
regenerations.
Controller improperly programmed.
Verify salt dosage and regeneration
interval settings. See 6. Programming,
page 28.
Flow indicator on
controller does
not display service
flow.*
Bypass valve in bypass position.*
Remove bypass valve from bypass
position.*
See 5.8. Bypassing, page 24.
Meter cable dislodged from valve.* Fully insert meter cable into valve.*
Meter clogged with debris.*
Remove and clean the meter.*
See 9.2. Cleaning and maintenance,
page 37.