9.2.10. DLFC cleaning
No. Operation
A Using a 39 mm wrench, unscrew and remove the flow washer housing (1).
B Remove the flow washer (2) from the flow washer housing (1).
C Clean or change the flow washer (2).
D Reverse above procedure steps to rebuild.
Mandatory
The flow washers (2) have to be installed with their chamfered side upfront the water
stream flow. Flow indication must be visible after the washer (2) is placed on the flow
washer housing (1).