INTELLICHEM
®
Controller Installation and User’s Guide
INTELLICHEM
®
Controller Installation and User’s Guide
11
1. Press the / Up/Down arrow button to scroll
through the main menu items. For this example
choose pH menu.
2. Press the Right arrow button to select the
pH menu.
3. Press arrow button to select pH Dosage (page
1 of 2). Press / to toggle between pH Dosage
page 1/2 and page 2/2.
4. From pH Dosage page 1/2, press the to select
Dose (feed method). To change the feed method
press / to change the selection: “by Volume” or
“by Time”.
5. Press the to select the next item. The cursor
moves down to the “Mixing Time” hours setting
(H:00).
6. Press the / to adjust the Mixing Time hours
between feeding acid. Press to select the
minutes. Press
/ to adjust the minutes. After adjustment, the
display shows the new setting. Note: Press either
/ button to scroll forward or backwards within
this sub-menu.
7. Select 1/2 page indicator. Press the / buttons to
select the next pH Dosage screen (2/2).
8. Use / buttons and / buttons to select and
change the “Dose” (amount of liquid dispensed
before waiting for a mix time), Limit (amount of
liquid dispensed in one day, Units (apply to dose
and limit) and clear dose limits setting.
9. Press the MENU to return to the previous pH
Dosage page 1/2 menu items.
10. Press the MENU again to exit pH Dosage menu.
Note: All settings are immediately save when
changed.
Navigating IntelliChem
®
Controller Menus
Press MENU / pH Menu pH Dosage
Example: To change the pH dosage settings (pH Dosage screens 1/2 and 2/2):
The following examples show how to navigate the main menus and sub-menus. Press
the MENU button to access the main menu. Press the Right arrow button to select
a menu item and select items in a sub-menu. Press / to select previous/next item
on a page. To change a menu setting or value press the / Up/Down arrow button.
Press the MENU button to exit and return to the previous menu items. Note: Settings are
automatically save when changed.
pH Dosage 2/2
Dose Limit Units
3 21 [oz]
Clear [Power-On]
pH Dosage 1/2
Dose: by Volume
Mixing Time:
H:00 M:59
pH Dosage 1/2
Dose: by Volume
Mixing Time:
H:09 M:59
pH Dosage
pH Setpt: 7.5
pH Tweak
pH Supplies
ORP Menu
Saturatn Index
Auto Setup
Conguration
pH Menu
ORP Menu
Saturatn Index
Auto Setup
pH OK 7.46
Mixing 00:07:03
ORP OK 450
Mixing 00:07:54
pH Menu
ORP Menu
Auto Setup
Conguration

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair intellichem and is the answer not in the manual?

Pentair intellichem Specifications

General IconGeneral
pH ControlYes
ORP ControlYes
DisplayLCD
Waterproof EnclosureYes
Enclosure RatingNEMA 4X
AlarmsYes
Operating Temperature32° to 122°F (0° to 50°C)
Humidity Range0% to 95% non-condensing
CommunicationRS-485
OutputsRelays for chemical feed pumps