16
17
IntelliSync Control and Monitoring System User's Guide
Alerts (IntelliSync™)
To access the Alerts page from the Dashboard, tap the bell icon (top right).
∙ Recent: Display recent device alerts.
∙ Severity: Display severe device alerts.
Alerts (IntelliFlo® Pumps)
To access the Alerts page from the Dashboard, tap the bell icon (top right).
The IntelliFlo® VSF Variable Speed and Flow Pump displays all alarms and
warnings on the control panel display. When an alarm or warning condition
exists, the corresponding light will be lit on the display. In the event of an
alarm: The alarm light will illuminate and all control panel buttons will be
disabled until the alarm is cleared. Pressing the Reset button will clear the
alarm once the fault condition has been resolved. In the event of a
warning: The warning light will illuminate, but the pump will continue to
run. The speed, flow or pressure limit that is causing the warning must be
adjusted in order to correct the warning.
IntelliFlo VSF Alerts and Warnings
Over Voltage: Indicates excessive supply voltage or an external water
source is causing the pump and motor to rotate thereby generating an
excessive voltage on the drives internal DC buss. The drive will restart 20
seconds after the over voltage condition clears.
Internal Error: Indicates that the self-monitoring motor control software
has encountered an error. Clear the alarm and restart the pump.
Speed Limit (Warning): The pump has detected that it has met the maxi-
mum allowed speed set in the Min/Max menu. The pump will continue to
run, but it will not achieve the desired speed.