21
3.1.1 Setting the measure condition
Opereation:
1. The distance measurement mode will be: Fine, Coarse, Repeat Fine,
Average Fine, Tracking.
2. Tilt correction mode will be: HV, V,
NO, Always off.
3. Collimator correction mode will be:
Yes or No.
4. CR correction mode will be:
K=0.142,K=0.2, No.
5. Sea Level correction mode will be:
Yes or No.
6. Target Type mode will be: Prism, No
Prism, Reflector.You could press
“Enter” to keep the setting or press cancelled.
3.1.2 Setting the units
Operation:
1. Angle unit mode will
be:DMS,GON,MIL.
2. Angle Precision mode will be: 1
second, 0.1 second or 0.5 second.
3. Distance Unit mode will be: Meter,
US Feet, Feet.
4. Distance precision mode will be:
1mm or 0.1mm.
You could press “Enter” to keep the
setting or press cancelled.