EasyManua.ls Logo

Pepperl+Fuchs IC-KP-B17-AIDA1 - Data Logging

Pepperl+Fuchs IC-KP-B17-AIDA1
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2014-02
100
IC-KP-B17-AIDA1
Web features
State:
The status of the response telegram appears in this field.
Data:
The data from the response telegram appear in this field (if available).
Log:
A list of received response telegrams appears in this field.
8.6 Data logging
You can track commands activated in the IDENTControl Compact in the Data logging window.
Select between 50, 100, 200, or 512 displayed lines. The current time appears at the top of the
window.
Example of logged lines
The following appears in the window:
0000029.987 CH1 rsp BUS 01 s:0 l:0005 64.03.03.03.03
0000029.845 BUS req CH1 01
Meaning of logged lines
When the time is 0000029.845, the bus sends the command 01 (=SF) to channel 1 of the
IDENTControl Compact. When the time is 0000029.987, the IDENTControl Compact sends
the response with the data packet to the bus.
Time stamp Sender Message type Receiver Command Statu s Data length Data
0000029.987 CH1 rsp BUS 01 s:0 l:0005 64.03.03
.03.03
0000029.845 BUS req CH1 01