Troubleshooting
2014-02
103
10 Troubleshooting
10.1 Fault/Status messages
Error messages which triggered the identification system
Error messages sent by the bus connection
Statu s Meaning
00h The command has been executed without error.
FFh The command is processing.
Statu s Meaning
01h The battery of the read/write tag is weak.
02h Reserved
03h Reserved
04h Incorrect or incomplete command or parameter not in the valid range.
05h No data carrier in the detection range.
06h Hardware error, e.g. error during self-test or R/W head defect.
07h Internal device error.
08h Reserved
09h The parameterized tag type is not compatible with the connected reading head.
0Ah Several tags in the detection range (UHF).
0Bh Reserved
0Ch Reserved
0Dh Reserved
0Eh Internal buffer overflow.
0Fh Reserved
Statu s Meaning
10h Reserved
20h Reserved
40h Incorrect or incomplete command or parameter not in the valid range.
TCP/IP: The specified length of the message does not match the actual length.