Installation and commissioning
30
8.04 Basic position of the machine drive unit
Switch on the machine.
Press the TE/speed key twice to select the input mode.
TE
No VAL
A 101 ON
TE
No VAL
C 798 11
TE
No VAL
C 800 ON
Select parameter 798“ by pressing the corresponding +/- key, and select service level C
(value “11“).
By pressing the corresponding +/- key, select parameter 800“ (rotation direction of the
motor).
By pressing the corresponding +/- key, select ON“ (reverse direction).