73
Fitting:
• Place the circuit board on the front housing panel.
• Secure the circuit board with screws 123, 124 and 125 (fig. 74).
• Mount connection plugs 2, 3, 9, 14, 15, 16, 17, 18, 19, 20, 21, 22, and 122 onto the circuit board.
• Mount the facing panel onto the front housing panel, making sure that both lugs 1 lock into place
(fig. 73).
• Attach the housing insert and secure with both torx screws.
• Attach the folding cover.
• After a running-in time of 10 - 15 min. check the adjustment of equal forward and reverse stitch
length in accordance with section 21 of the service manual.