75
Fitting:
Mount the keypad onto the circuit board whilst making sure that the lugs 126 and 127 lock in
completely behind the circuit board (fig. 76).
Mount the facing panel onto the front housing panel and make sure that both lugs 1 lock fully into
place (fig. 75).
Attach the housing insert and secure with both torx screws.
Attach the folding cover.
Carry out a functional test for all keys.
After a running-in time of 10 - 15 min. check the adjustment of equal forward and reverse stitch length
according to section 22 of this service manual.