INTELIA 02 TECHNICAL SPECIFICATIONS
Saeco International Group Rev. 01 / September 2011 Page / 03
2.2. Machine parameters and performance
PRODUCT
QUANTITY
Minimum
quantity
(Puls.)
Default
quantity
(Puls.)
Maximum
quantity
(Puls.)
User
programmable
Programm. by
Production /
Service
Espresso 50 165 600 Yes No
Long coffee 70 440 600 Yes No
Pre-ground No
Hot water Continues until the water supply has been exhausted (capacitive sensor)
Steam
pannarello
(frother)
Continues until the water supply has been exhausted (capacitive sensor)
RINSE Initial rinse Final rinse
When performed When the machine is switched
on and the boiler temperature is
≤ 50°C
When the machine is switched off
electronically, manually or auto-
matically after 30', if at least one
coffee has been dispensed, be-
fore switching off
No. of pulses 180 80
Stopping option Yes, by pressing any key Yes, by pressing any key
User disable option No No
Production/Service de-
partment disable option
No No
No. of pulses user adjust-
ment option
No No
No. of pulses Production/
Service department ad-
justment option
No No
Pulse range
(Min. – Max.)
No No
02
Descaling cycle frequency
Hard-
ness
Water hardness Without water fi lter With water fi lter
1 Soft (up to 7°dH) 240 litres (480,000 pulses) 480 litres (960,000 pulses)
2 Medium (7° - 14°dH) 120 litres (240,000 pulses) 240 litres (480,000 pulses)
3 Hard (15° - 21°dH) 60 litres (120,000 pulses) 120 litres (240,000 pulses)
4 Very hard (over 21°dH) 30 litres (60,000 pulses) 60 litres (120,000 pulses)
The default water hardness level is 4. Each litre of water corresponds to approximately
2,000 pulses.