INTELIA 07 DISASSEMBLY
Saeco International Group Rev. 01 / September 2011 Page / 11
09
7.15. Dispenser assembly
7.16. Valve disassembly
7.14. Boiler
Unscrew the marked screw and disconnect the
electrical and water circuit connections.
Loosen the screws as illustrated and remove the front panel to
access the screws which x the dispenser cover into place.
Press the hooks as illustrated and slide out the dispenser assembly.
Slide out the fork as illustrated.
Release the boiler cover
and take it off.
Loosen the screws as illustrated and remove the front panel to
access the screws which x the dispenser cover into place
Loosen the screws as
illustrated and remove the
boiler pin (A)
A