INTELIA 05 TROUBLESHOOTING
Saeco International Group Rev. 01 / September 2011 Page / 11
01
The coffee grinder is blocked (grinder blades jammed or sensor not
reading properly)
03
The brewing unit is blocked in work position (microswitch not released
in up position after 3", torque error trying to move down, descent time
out exceeded)
04
The brewing unit is blocked in home position (microswitch not released
in down position after 3", torque error trying to move up, ascent time
out exceeded)
05
Water circuit / fl ow meter problems (water circuit blocked or no fl ow
meter signal)
10
Boiler temperature sensor short circuited
11
Boiler temperature sensor open circuit
14
The boiler temperature has exceeded the maximum allowed value
(165°c)
15
The boiler temperature has not increased by x°C in y sec (boiler power
supply disconnected, incorrect boiler fi tted must be a 1300W boiler, par-
tial power supply to boiler, cut out thermostat tripped)
19
Mains voltage trouble
5.3. Error codes