EV Charge Control Basic
8 / 68
PHOENIX CONTACT 106377_en_04
AWG according to UL/CUL AWG 30 ... 12
Conformance/approvals
CE-compliant √
Low-voltage directive 2006/95/EC
Safety test IEC 61010-1
Function test IEC 61851-1, Appendix A
Air clearances and creepage
distances
IEC 61010-1
Order number 1622452 1622453 1622459 1622460
EV-CC-AC1-M3- CBC-SER-HS CBC-SER-PCB CC-SER-HS CC-SER-PCB
Conformance with EMC Directive 2004/108/EC and Low-Voltage Directive 2006/95/EC
Noise immunity test according to EN 61000-6-2
Protection for housing connections
Electrostatic discharge (ESD) EN 61000-4-2 Criterion B ±6 kV (contact discharge)
±8 kV (air discharge)
Electromagnetic HF field EN 61000-4-3 Criterion B 80 MHz ... 1 GHz, field strength 10 V/m, 80% AM
(1 kHz)
1 GHz ... 3 GHz, field strength 10 V/m, 80% AM
(1 kHz)
Protection for inputs and outputs, AC power connections
High frequency, asymmetrical EN 61000-4-6 Criterion A 150 kHz ... 80 MHz, 10 V, 80% AM (1 kHz)
Fast transients (burst) EN 61000-4-4 Criterion B ±2.2 kHz (peak)
5/50 ns (t
r
/t
n
)
5 kHz rep. frequency
Overvoltages EN 61000-4-5 Criterion B 1.2/50 ns (8/20) µs (t
r
/ t
h
)
Up to ±1 kV, wire-to-wire
Up to ±2 kV, wire-to-ground
Voltage dip EN 61000-4-11 Criterion B
Criterion C
Criterion C
0% for one period
40% for 10/12 periods
70% for 25/30 periods
Voltage interruption EN 61000-4-11 Criterion C 0% for 250/350 periods
Protection for signal connections
High frequency, asymmetrical EN 61000-4-6 Criterion A 150 kHz ... 80 MHz, 10 V, 80% AM (1 kHz)
Fast transients (burst) EN 61000-4-4 Criterion B ±2.2 kHz (peak)
5/50 ns (t
r
/t
n
)
5 kHz rep. frequency
Overvoltages EN 61000-4-5 Criterion B 1.2/50 ns (8/20) µs (t
r
/ t
h
)
Up to ±1 kV, wire-to-ground