RAD-...-IFS
32 / 198
PHOENIX CONTACT 105542_en_05
RS-485 front module
The RAD-RS485-IFS RS-485 front module for I/O extension modules allows Radioline sta-
tions to be operated via a 2-wire RS-485 bus system. The front module can be extended
with up to 32 I/O extension modules via the DIN rail connector.
You can connect Radioline RS-485 stations to a Radioline master wireless module and
thereby extend the wireless network. All devices in the wireless network and in the RS-485
network form one system. All stations are addressed uniquely using the yellow thumbwheel.
The I/O signals can be distributed easily between all the stations, regardless of the medium
used.
Figure 4-2 I/O-to-I/O, wireless, and RS-485
The RAD-RS485-IFS RS-485 front module is not described in this user manual.
For additional information, visit phoenixcontact.com/product/2702184
.
RS-485 RS-485 RS-485
RS-485
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
1
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-D
AIO6-IFS
IO-MAP
OFF ON
DIP-1
1
2
3
4
PWR
DAT
ERR
DO4
DO3
DO2
DO1
DI1L
DI2L
DI1H
DI2H
DI1
DI2
UL1 +I1 -I1
U1 I1
1
COM1
COM2
NO1
NO2
NC1
NC2
1 2
RAD-DOR4-IF
S
8 8
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
2 2
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-DI4-IF
S
DI1L
DI2L
DI1H
DI2H
DI1
DI2
PWR
DAT
ERR
DI4
DI3
DI2
DI1
DI3L
DI4L
DI3H
DI4H
DI3
DI4
7 7
IO-MAP
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
3
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-DOR4-IF
S
8 8
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
2 2
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
4
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-DI4-IFS
DI1L
DI2L
DI1H
DI2H
DI1
DI2
PWR
DAT
ERR
DI4
DI3
DI2
DI1
DI3L
DI4L
DI3H
DI4H
DI3
DI4
8 8
IO-MAP
RAD-AI4-IFS
PWR
DAT
ERR
2 2
IO-MAP
OFF ON
DIP-1
1
2
3
4
Pwr1
Pwr2
+I1
+I2
-I1
-I2
Pwr3
Pwr4
+I3
+I4
-I3
-I4
RAD-2400-IF
S
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
0
2
SET
D(A)
D(B)
RX
COM
1
TX
NO
2
GND
NC
1
+24V
RSSI
+
0V
ANT
RSSI
-
RAD-DOR4-IF
S
8 8
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-DAIO6-IFS
IO-MAP
OFF ON
DIP-1
1
2
3
4
PWR
DAT
ERR
DO4
DO3
DO2
DO1
DI1L
DI2L
DI1H
DI2H
DI1
DI2
UL1 +I1 -I1
U1 I1
1
COM1
COM2
NO1
NO2
NC1
NC2
1 2
RAD-RS485-IFS
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
LINK
0
5
SET
D(A)
D(B)
COM
1
NO1
NC1
+24V
0V
RAD-DOR4-IF
S
7 7
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
4 4
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-RS485-IFS
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
LINK
0
6
SET
D(A)
D(B)
COM
1
NO1
NC1
+24V
0V
RAD-DOR4-IF
S
7 7
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
4 4
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3
RAD-RS485-IFS
RAD-ID
S-PORT
PWR
DAT
ERR
RXTX
LINK
0
7
SET
D(A)
D(B)
COM
1
NO1
NC1
+24V
0V
RAD-DOR4-IF
S
7 7
IO-MAP
PWR
DAT
ERR
DO4
DO3
DO2
DO1
OFF ON
DIP-1
1
2
3
4
COM1
NO1
NC1
COM2
NO2
NC2
COM3
NO3
NC3
COM4
NO4
NC4
RAD-AO4-IFS
PWR
DAT
ERR
4 4
IO-MAP
OFF ON
DIP-1
1
2
3
4
U1
U2
I1
I2 2
1
U3
U4
I3
I4 4
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phoenix Contact RAD IFS Series and is the answer not in the manual?

Phoenix Contact RAD IFS Series Specifications

General IconGeneral
BrandPhoenix Contact
ModelRAD IFS Series
CategoryTransceiver
LanguageEnglish

Related product manuals