PDP-507CMX
188
1234
1234
C
D
F
A
B
E
[QSD]: Response format
Command Format
Data Arrangement Data Length Output Example
• SD data
• SD subcategory (SQ-IC)
• SD subcategory (MDU-IIC)
• SD subcategory (TEMP)
[QSD]
1
0 No SD
1 SQ-IC
2 MDU-IIC
3 RST2
4 TEMP
0 No SD-Sub data
1 Communication error
2 Drive stop
3 BUSY
0 No SD-Sub data
1 EEPROM
2 BACKUP
0 No SD-Sub data
1 TEMP1
2 Reserved
3 DAC
6 Version mismatching
3Byte QSD
Latest SD data
2
1byte 1
Latest SD subcategory data
3
1byte 0
Data from the hour meter for the latest SD
4
8byte 00752013
Second latest SD data
5
1byte 5
Second latest SD subcategory data
6
1byte 0
Data from the hour meter for the second latest SD
7
8byte 00495204
Third latest SD data
8
1byte 2
Third latest SD subcategory data
9
1byte 3
Data from the hour meter for the third latest SD
10
8byte 00100355
Fourth latest SD data
11
1byte 2
Fourth latest SD subcategory data
12
1byte 5
Data from the hour meter for the fourth latest SD
13
8byte 00075620
Fifth latest SD data
14
1byte 1
Fifth latest SD subcategory data
15
1byte 0
Data from the hour meter for the fifth latest SD
16
8byte 00000852
Sixth latest SD data
17
1byte 2
Sixth latest SD subcategory data
18
1byte 5
Data from the hour meter for the sixth latest SD
19
8byte 000000451
Seventh latest SD data
20
1byte 0
Seventh latest SD subcategory data
21
1byte 0
Data from the hour meter for the seventh latest SD
22
8byte 00000000
Eighth latest SD data
23
1byte
0
0
Eighth latest SD subcategory data
24
1byte
00000000Data from the hour meter for the eighth latest SD
CS 2Byte
8byte
7D
ECO
All operations To acquire data on the shutdown logs Return data: 3 (ECO)+80(DATA)+2(CS)= 85 Byte
Effective Operation Modes Function Remarks