32.2 Function Master
Software functions of ATR620 include operating as Master. This feature
allows serial communication of sever
al controllers to control more zones
of the same kiln. Function is enabled entering 0 on parameter 50. Master
will communicate Start/Stop of cycle and setpoint values to the
connected slave units (which must be configurated for remote setpoint
on parameter
s 1 and 5). Communication follows the broadcast mode: all
controllers receive data. If Waiting function is enabled on Master, it will
read process values of the first 16 connected controllers (slave address
1 to 16 on parameter 50) and it will check eventu
al delay of any
connected zone.
32.3 Word addresses ATR620
Modbus
address
Description Read
Write
Reset
value
1 Process AN1 R 0
2 Process AN2 R 0
3 Ambient temperature R 0
4 Output % process 1 R/W 0
5 Output % process 2 R/W 0
6 Setpoint 1 R/W EEP
7 Setpoint 2 R/W EEP
8 Remote setpoint R EEP
9 Setpoint 1 via serial communication R/W EEP
10 Setpoint 2 via serial communication R/W EEP
11 Delaied start (waiting time at start) R/W EEP
15 Start via serial communication R/W 0
21 Parameter 1 R/W EEP
22 Parameter 2 R/W EEP
23 Parameter 3 R/W EEP
24 Reserved R ?
25 Parameter 5 R/W EEP
26 Parameter 6 R/W EEP
27 Parameter 7 R/W EEP
28 Parameter 8 R/W EEP
29 Parameter 9 R/W EEP
30 Parameter 10 R/W EEP
31 Parameter 11 R/W EEP
32 Parameter 12 R/W EEP
33 Parameter 13 R/W EEP
34 Parameter 14 R/W EEP