4.2.58 green-ethernet led interval
Command:
green-ethernet led interval <0~24> intensity <0-100>
<0~24> Interval from 00.00 to 24.00 (00 is used to start at midnight,
while 24 is used to stop at midnight).
intensity LEDs intensity.
<0-100> Intensity from 0% (LEDs OFF) to 100%
Default:
N/A
Usage Guide:
To configure LED Power reduction for interval time.
Example:
To configure LED Power reduction as tabled below.
Switch# configure terminal
Switch (config)# green-ethernet led interval 8-13 intensity 80
4.2.59 green-ethernet led on-event
Command:
green-ethernet led on-event error | link-change <0-65535>
error Set LEDs intensity to 100% if an error occurs.
link-change Specifies how long to turn LEDs intensity into 100%, when a link changes state.
<0-65535> Number of seconds to set LEDs intensity at 100% at link change.
Default:
N/A
Usage Guide:
To configure LED Power on-event to trigger LED light
Example:
To configure LED Power on-event as tabled below:

Table of Contents

Other manuals for Planet GS-5220-16S8C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planet GS-5220-16S8C and is the answer not in the manual?

Planet GS-5220-16S8C Specifications

General IconGeneral
BrandPlanet
ModelGS-5220-16S8C
CategorySwitch
LanguageEnglish

Related product manuals