EasyManua.ls Logo

Pneumercator TMS3000 - Shift Inventory Log; Thefts

Pneumercator TMS3000
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION & MAINTENANCE MANUAL TMS2000/3000
TMS Operations and Maintenance Manual.docx February 12, 2018
PAGE 17
2.4.1.1 SHIFT INVENTORY LOG
Log
Max
Inventory Inventory Scheduled inventory snaphots 36
deLivery Deliveries Product delivered to storage tank 12
SALES Bulk Sales Product sold from storage tank 24
tHEFtS Thefts Unauthorized withdrawal from tank 6
Orders Product Reordering Report Product reordering report 1x12
Water Bottom Water Removal Removal of bottom water 1x12
tank Leak In-Tank Leak Test Detailed Results Detailed In-Tank Leak Test Results 12
Leak Hist In-Tank Leak Test History In-Tank Leak Test Summary Results 14x12
LIne Leak LS300 Line Leak Test LS300 Line Leak Test Results 1x8
ALArMS Alarms Alarms 24
Events Events Events/Errors 8
return Return Exits LOG menu
Inventory Inventory: A scheduled Inventory data capture typically used as a Shift Report.
Record Storage Capacity: 36. 1 Tank Channel per record.
TMS Configuration Prerequisites:
Configuration menu, Inventory submenu: Defines Times and Days of Week.
Group ID: Record Number.
Record Identification Data:
mm-dd Date (Month-Day): Date the scheduled Inventory Snapshot was recorded.
Note: an empty record will show 00-00.
HH'mm Time (HourMinute): Time the scheduled Inventory Snapshot was recorded.
Note: time stored in 24 hr. format
Examples: 12’00 = 12 Noon 23’59 = 11:59 PM 00’00 = Midnight
tank Name Tank Name: As Assigned in the Configuration menu, Tank submenu.
Prod type Product Type: As Assigned in the Configuration menu, Tank submenu.
tank id Tank ID Number: As Assigned in the Configuration menu, Tank submenu.
Captured Data:
Prod Ht Product Height: Total Liquid Level.
Note: MP452 reports Oil Level.
Gr VoL Gross Volume: Total Liquid Volume.
Note: MP452 reports Oil Volume.
Net VoL Net Volume: Total Net (Temperature-Compensated) Liquid Volume.
Note: MP452 reports Net Oil Volume.
P VoL Percent Volume: Gross Volume/Tank Capacity displayed as a percentage.
ULLage Ullage: Gross Volume required to fill tank to defined Ullage Threshold. See Configuration menu,
Header submenu, Ullage Limit
h2o Ht Bottom Water Height: Bottom Water Level.
temp Temperature: Average Liquid Temperature.
Exit Inventory submenu:
Return Return: Press EDIT (TEST) to exit Inventory submenu.
Note: Press STEP (MODE) to return to top of Inventory submenu showing mm-dd (Month-Day)