EasyManua.ls Logo

Pneumercator TMS3000 - Error Conditions

Pneumercator TMS3000
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION & MAINTENANCE MANUAL TMS2000/3000
TMS Operations and Maintenance Manual.docx February 12, 2018
PAGE 75
Error Conditions:
All Error
conditions
are recorded in the Event Log and are printed automatically
if printer
is enabl
ed. Error
condi
tions
are also user
programmable
to auto-
dial out upon
alarm.
Errors
will produce
an audible
alarm
and appear
on the TMS
display
showing the specific
error
condition
and code
number.
Errors
conditions
can only
be silen
ced by ackn
owledging
the Front
pane
l or Edit enable
buttons.
The
displayed
error
message
will continue
until the condi
tion is
correc
ted.
Event Descr
iption for Error
s
Error # Description
Item ID
Nam
e
Note
s
1
BOOT
PROM CHECKSUM
ERR
OR
n/a
n/a
Trouble
with boot prom
firmware chip in U4 socke
t
2
FLASH PROM CHECKSUM
ERR
OR
n/a
n/a
Trouble
with flash prom
firmware chip in U5 socket
3
FLASH
PROM WRI
TE ERROR
n/a
n/a
4
FLASH
PROM ER
ASE ERROR
n/a
n/a
5
EEPROM CHECKSUM ERROR
n/a
n/a
Trouble
with CM1 chip in U2 (TMS3000) or U14 (TMS20
00) socket
10
PROBE SYNC ERROR
probe
#
n/a
Unintelligi
ble signal being r
eceived from probe
11
PROBE TIMEOUT ERROR
probe #
n/a
No signal bei
ng detected fro
m probe
20
SENS
OR FAULT - SHOR
T
CIRCUI
T
sensor #
sensor
name
Wiring fault
with all sensors
except
ES825-200F
21
SENS
OR FAULT - OPEN
CIRCUI
T
sensor #
sensor
name
22
SENS
OR FAULT
sensor #
sensor name
Wiring fault
with ES825-2
00F
Note: IS
CC or Intrinsically
Safe Contact C
losure is syno
nymous
with Leak/Pt. Level
Sensor

Table of Contents

Other manuals for Pneumercator TMS3000

Related product manuals