EasyManua.ls Logo

Pneumercator TMS3000 - Bottom Water Removal Report; Alarms

Pneumercator TMS3000
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION & MAINTENANCE MANUAL TMS2000/3000
TMS Operations and Maintenance Manual.docx February 12, 2018
PAGE 22
2.4.1.6 BOTTOM WATER REMOVAL REPORT
Log
Inventory Inventory
deLivery Deliveries
SALES Bulk Sales
tHEFtS Thefts
Orders Product Reordering Report
Water Bottom Water Removal
tank Leak In-Tank Leak Test Detailed Results
Leak Hist In-Tank Leak Test History
LIne Leak LS300 Line Leak Test
ALArMS Alarms
Events Events
return Return
Water Bottom Water Removal: A transaction log that represents the withdrawal of bottom water from the tank.
All transactions depend on the TMS Clock functionality to be recognized.
Record Storage Capacity: 12, 1 per Tank Channel
TMS Configuration Prerequisites:
Configuration menu, Probe submenu, Motion Height Band: Defines Transaction recognition
Configuration menu, Probe submenu, Minimum Logged Volume: Defines Transaction Logging
Group ID: Tank Channel Number.
Record Identification Data:
mm-dd Date (Month-Day): Date the Bottom Water Removal was recorded.
Note: an empty record will show 00-00.
HH'mm Time (Hour’ Minute): Time the Bottom Water Removal was recorded.
Note: time stored in 24 hr. format
Examples: 12’00 = 12 Noon 23’59 = 11:59 PM 00’00 = Midnight
tank Name Tank Name: As Assigned in the Configuration menu, Tank submenu.
Prod type Product Type: As Assigned in the Configuration menu, Tank submenu.
tank id Tank ID Number: As Assigned in the Configuration menu, Tank submenu.
Captured Data:
Prod Begi Product Begin Volume: Gross Product Volume at the Beginning of the Water Removal.
h2o Begin Water Beginning Volume: Gross Volume of Bottom Water at the Beginning of the Water
Removal.
Beg totaL Gross Beginning Volume: Total Gross Volume at the Beginning of the Water Removal.
Prod End Product Ending Volume: Gross Product Volume at the End of the Water Removal.
h2o End Water Ending Volume: Gross Volume of Bottom Water at the End of the Water Removal.
End totaL Gross Ending Volume: Total Gross Volume at the End of the Water Removal.
P VoL Percent Ending Volume: Gross Volume/Tank Capacity displayed as a percentage.
ULLage Ending Ullage: Gross Volume required to fill the storage tank to defined Ullage Threshold. See
Configuration menu, Header submenu, Ullage Limit.
Exit Water submenu:
Return Return: Press EDIT (TEST) to exit Water submenu.
Note: Press STEP (MODE) to return to top of Water submenu showing mm-dd (Month-Day)