OPERATION MANUAL TMS4000
TMS4000 Operation Manual 2018-08-03.docx August 3, 2018
PAGE 15
Meter Format: The number of meters can be selected in single, dual or four-meter, or the meter
window can be disabled altogether. The individual meters may be further customized from the real-
time screen as described later in this section.
Grid Column Selects: The specific columns presented on the tabular display may be selected here.
If more columns are selected than fit on the width of the display, the user may scroll by dragging their
finger left-right across the tabular display. Note that the Tank ID, Tank Name, Status, and Alarms
columns cannot be disabled.
Gross Volume: Temperature Uncompensated volume
Net Volume: Temperature-Compensated Volume.
% Volume: Gross Volume/Tank Capacity x 100%.
Ullage: Maximum delivery amount. See the Header section in Configuration for details on
adjusting the maximum fill point.
Product Height: Total height of liquid. For O/W Separator tanks, this is a measurement of the
oil height.
Water Height: Bottom water height or total water height for O/W Separator Tanks.
Product Temperature: Volume-weighted average liquid temperature.
Bar Graph Format: Choices for configuring the bar graph are as follows:
Disabled
Product Only
Product and Water
Product and Temperature
Screen Appearance: This section offers settings for configuring the Day/Night Mode, Screen Save,
and Brightness features as described below:
Day/Night: The LCD screen has two different color schemes to improve visibility for both Day and
Night conditions. This feature can be set to automatically toggle between these two schemes using
the information from the Day/Night sensor on the face of the TMS4000 or may be manually toggled
by clicking on the Moon/Sun icon.
Screen Save: Dims the LCD to 3% brightness after a five-minute time delay. The screen is
reactivated when the screen is touched or if an alarm or activity occur.
Brightness: The LCD screen brightness may be manually adjusted using the slider (default is
75%) or may be automatically adjusted using the information from the Day/Night sensor on the face
of the TMS4000.