7.3
2002 RPM Limiter Systems
M
o
d
e
l
Temperature MFD / MFI / Gauge
R
P
M
L
i
i
t
M
o
d
e
l
e
p
e
a
t
u
e
Sensor “ON (F°/C°)
/
/
G
a
u
g
e
Display
R
P
M
L
i
m
i
t
Freedom 160°±8° F/71° C Fuel Gauge
Oil and Overheat=
LED Light
Overheat -- 3500 RPM
Virage 160°±8° F/71° C Oil / Heat / Fuel Overheat -- 3500 RPM
Virage TX 160°±8° F/71° C Oil / Heat / Fuel Overheat -- 3500 RPM
Virage i EMM Controlled
Oil / Heat / Fuel
Overheat -- S.L.O.W.
3500 RPM
Virage TXi EMM Controlled
Oil / Heat / Fuel
Overheat -- S.L.O.W.
3500 RPM
Genesis 237°±8° F/114° C Oil / Heat / Fuel Overheat -- 3500 RPM
Genesis i EMM Controlled
Oil / Heat / Fuel
Overheat -- S.L.O.W.
3500 RPM
RPM Limiter Function
If the engine overheats, the thermal switch becomes conductive and provides a ground path for the tan wire lead-
ing from the terminal board and the Multi-Function Display. The Multi-Function Display will display a HOT warn-
ing message, the warning light will flash, and the engine RPM will be limited to approximately 3500 RPM. A circuit
within the CDI senses the ground path connection and activates the limiting function.
Important Note: When the engine overheat circuit has caused the system to limit, it will continue to limit until
both of the following conditions are met:
1. The problem that caused the initial limiting must be corrected (cool engine);
AND
2. The operator must momentarily release the throttle and allow the RPM to fall below 3500.
Reverse RPM Limiters
The following 2002 watercraft will limit in reverse mode:
S Virage -- Manual Reverse
S Virage TX -- Manual Reverse
S Virage i -- Manual Reverse
S Virage TXi -- Manual Reverse
S Genesis -- PERCt
S Genesis i -- PERCt
PERCt = Polaris Electronic Reverse Control
The 2002 Virage, Virage TX, Virage i, and Virage TXi are built with a manual reverse system. When the reverse
lever is engaged in either neutral or reverse, a switch is contacted, putting the CDI in limiting mode.
The 2002 Genesis, and Genesis i will limit RPM whenever the reverse control thumbpad is pressed in either neu-
tral or reverse.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris WATERCRAFT Virage TXi and is the answer not in the manual?

Polaris WATERCRAFT Virage TXi Specifications

General IconGeneral
BrandPolaris
ModelWATERCRAFT Virage TXi
CategoryBoat
LanguageEnglish

Related product manuals