10. Mid-Cycle Failure (Camera stops before completing normal, full cycle)
• Check Flex connection to Logic Switch Block (See Figure 5-3).
• Check condition of DKEC Switch (See Figure 1-15).
• Check for solder slivers on Flex at Shutter connection (See Figures 4-21 and 4-22).
• Check condition of Outer/Inner Door Stop Links (See Figures 1-16 and 4-42).
• Check condition of Flex Plug: broken snap? (See h, Figure 4-32).
• Check condition of Battery Contacts: clean, not deformed, etc. (See i , Figure 4-32, and
Page 4-33).
• Check condition of Door Latch (on Chute) (See Figure 4-6).
• Check condition of Full Chamber Link (See Figure 2-28).
• Check Full Chamber Switch wire: is it stuck on Gear Drive Cover? (See Figure 2-28).
11. No Self-Timer
• Check condition of Self-Timer Spring (See Figure 4-2).
• Check condition of Self-Timer Switch wires on Logic Switch (See Figure 5-3).
• Check condition of Flex connection to Logic Switch (See Figure 5-3).
• Check for solder slivers on Flex at Shutter connection (See Figures 4-21 and 4-22).
12. Film Speed Switch Failure
• Check condition of Film Speed switch wires in Logic Switch (See Figure 5-3).
• Check condition of Flex connection to Logic Switch (See Figure 5-3).
• Check for solder slivers on Flex at Shutter connection (See Figures 4-21 and 4-22).